Whirlpool AD030 Dehumidifier User Manual


 
5. Remove the rear grille by pulling out at
bottom and dropping grille down.
6. Lift cabinet off unit base.
7. Brush coils clean, if necessary, with
warm water and a mild detergent. Rinse
and dry thoroughly. Be sure the power
supply cord is disconnected from the
electrical outlet.
NOTE: The compressor is sealed and
needs no oiling. The fan motor is
prelubricated and does not require
further oiling under normal operating
conditions. However, if the dehumidifier
is operated under severe environmental
conditions (dust, dirt, high temperatures)
the fan motor should be oiled annually.
Follow the instructions in Step 8.
Coils
8. Oil the fan motor through the tubes
provided. An easy-to-use capsule of
especially recommended oil (Part
No. 10943) is available from your
nearest authorized Whirlpool@
service company, or use SAE #20
non-detergent oil.
9. Wash all plastic parts with a soft cloth,
warm water and a mild detergent. Rinse
and dry them with a soft cloth.
10. Replace cabinet and grille(s).
11. Reconnect dehumidifier to power
supply.
12