Whirlpool ACS072XG Air Conditioner User Manual


 
ELECTRICAL REQUIREMENTS
PLUG TYPE
115-volt models with amperes
up through 7.5
115-volt models with amperes
from 7.6 to 12.0
Receptacle wiring
Receptacle wiring should be a minimum
of 14 gauge. Use copper wire only. It is
the responsibility of the consumer to
provide proper and adequate receptacle
wiring, installed by a qualified electrician.
Observe national electrical codes and all
local governing codes and ordinances.
Electrical requirements
A 115~volt (103.5 min., 126.5 max.),
60-H& AC-only, 15-ampere fused
electrical supply is required. A time-delay
fuse or circuit breaker required. It is
required that a separate circuit, serving
only this air conditioner, be provided.
Electrical connection
Electrical ground is required on this air
conditioner.
Recommended ground method
For your personal safety, this air
conditioner
must
be grounded. This air
conditioner is equipped with a power
supply cord having a 3-prong ground
plug. To minimize possible shock hazard,
the cord must be plugged into a mating
3-prong ground-type wall receptacle,
grounded in accordance with the National
Electrical Code ANSVNFPA 70 - latest
edition and local codes and ordinances.
If a mating wall receptacle is not
available, it is the responsibility of the
customer to have a properly grounded
3-prong wall receptacle installed by a
qualified electrician.
6