Whirlpool 250 Furnace User Manual


 
SERVICE
12.08.1997 / Page 2 AKM 250/WH Whirlpool Europe
Doc. No: 4812 715 16755 8571 250 35010 Customer Service
Technical data
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
PCS-kW
Rated
consumption
Reducedheat
capacity
PCS-kW
Gas pressure (mbar)
min. rat. max.
Natural Gas
(Methane)
G 20
large
medium
small
128
94
79
3,00
1,65
1,00
286 l/h
157 l/h
95 l/h
0,60
0,35
0,30
17 20 25
Natural Gas
(Cylinder)
G 30
large
medium
small
85
65
50
3,00
1,65
1,00
218 g/h
120 g/h
73 g/h
0,60
0,25
0,30
20 28-30 35
Natural Gas
(Cylinder)
G 31
large
medium
small
85
65
50
3,00
1,65
1,00
214 g/h
118 g/h
71 g/h
0,60
0,25
0,30
25 37 45
Type of gas used Appliance
model
Total rated heat
capacity
PCS-kW
Total rated
consumption
Air required for
burning m
3
/h
G20 20 mbar 4G 7,30 695 l/h 14,6
G30 28-30 mbar 4G 7,30 531 g/h 14,6
G31 37 mbar 4G 7,30 521 g/h 14,6
1. Medium Burner
2. Medium Burner
3. Large Burner
4. Small Burner
Voltage: 230 V
Frequency: 50 Hz