Westinghouse FG6RL Furnace User Manual


 
213B-0506 (Replaces 213B-0504)
Westinghouse products are manufactured and distributed by NORDYNE.
Approx. CFM
Airflow
@ 0.5" WC
12 = 1200
16 = 1600
FG 6 R
100
C 16L
C = U.S. / Canada
Design Series
L =Downflow,
Condensing
Residential
Gas
Heating Input - Btuh
040 = 40,000
060 = 60,000
080 = 80,000
100 = 100,000
120 = 120,000
MODEL IDENTIFICATION CODE
B
Cabinet Width
A = 14 1/4
B = 19 3/4
C = 22 1/2
O'Fallon, MO
VENTING
All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below
for specified sizes and allowable lengths.
Before purchasing this appliance, read important energy cost
and efficiency information available from your retailer.
Specifications and illustrations subject to change without notice
and without incurring obligations. Printed in U.S.A. (05/06)
VENT TABLE
* NOTE:
1. Subtract 2.5 ft. for each
additional 2" elbow and 3.5 ft.
for each additional 3" elbow.
2. Two 45 degree elbows are
equivalent to one 90° elbow.
3. One short radius elbow is
equivalent to 2 long radius
elbows.
4. Do not include termination
elbows in calculation of vent
length.
5. This table is applicable for
elevations from sea level
to 2000 ft. For higher
elevations decrease vent pipe
lengths by 8% per 1000 ft. of
altitude.
6. Only the above pipe materials
are approved for use with FG6
Condensing Furnaces.
ACCESSORY VENT KITS
Kit
Description
2" PVC 3" PVC 4" PVC
Horizontal
Exterior Vent
Mounting Kit
9023730 9023750 9023760
Neutralizer Kit
(all models)
9023770
APPLICATION SINGLE PIPE LENGTH (ft.) DIRECT VENT, DUAL PIPE LENGTH (ft.)
with 1 long radius elbow** with 1 long radius elbow on each pipe**
PVC,CPVC or ABS Outlet Outlet Inlet/Outlet Inlet/Outlet Inlet/Outlet
SCH. 40 Pipe Size 2" 3" 2" 2" 3" 2" 3" 3"
80 150 404050509090
Models 060 & 080 60 150 30 30 35 35 90 90
Models 100 & 120 30 150 15 15 25 25 90 90
Models 040
Kit Order Number
U.S. LP Conversion Kit
(0 to 10,000 ft.)
904090A
Canadian LP Gas Conversion Kit
(0 to 4,500 ft.)
904091A
Fossil Fuel Kit 914762
Downflow Sub-Base A Cabinet 902974
B Cabinet 902677
C Cabinet 904108
Variable Speed Blower Kit
For "A" Cabinets
904231
Variable Speed Blower Kit
For "B" & "C" Cabinets
904075