Westinghouse 81104 Indoor Furnishings User Manual


 
4
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These
fixtures meet all UL specifications.
1. Turn off power at circuit box to avoid possible electric shock.
2. Thread mounting screws (A) into mounting bar (B) (may be preinstalled) (see fig. 1).
3. Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).
4. Line up holes in canopy (E) with holes in fiberglass insulation (if applicable).
5. Identify color coding of fixture wires (see fig. 2).
6. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against
black outlet box wire. Do not twist wires.
7. Fit wire connector (F from fig. 1) over wires and twist until there is a firm connection. If
wire connector (F) easily comes off, reattach and check again for a firm connection.
8. Repeat steps 6 and 7 with the white (group B from fig. 2) fixture wires and outlet box wires.
9. Partially thread green grounding screw (G) into side hole (H) on mounting bar (B) (see fig. 1).
10. Wrap ground wire from fixture around green grounding screw (G) leaving enough excess
wire to then connect ground wire and outlet box wire with wire connector (F) (if applicable).
11. Tighten green grounding screw (G).
12. Tuck wires inside outlet box (C) (see fig. 1).
MOUNTING AND WIRING INSTRUCTIONS
FIXTURE ASSEMBLY INSTRUCTIONS
Warning: This fixture is for indoor use only.
1. Raise canopy (E) to ceiling allowing mounting screws (A) to protrude through openings in
canopy (E) and secure into place with cap nuts (I).
2. Install lamp(s). Do not exceed recommended wattage.
3. Place glass shade (J) into holder (K) and secure with thumb screws (L).
4. Turn power back on at circuit box.