CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal
between the fixture and the mounting surface by using silicone or similar caulking.
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These
fixtures meet all UL specifications.
1. Turn off power at circuit box to avoid possible electric shock.
2. Thread mounting screws (A) into mounting bar (B) approximately 1/4 inch (see fig. 1).
3. Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).
4. Remove canopy loop (H) and fixture loop (K) (from figure 1).
Cut wire to a length of at least
6 inches, then strip the insulation from the end of each wire. If unsure how to strip the wire
insulation, do not proceed.
Contact an electrician.
5. Place canopy (L) onto nipple of top assembly (Q), then secure with lock washer (G) and hex
nut (E).
6. Feed wires through the canopy (L) and nipple (F).
7. Identify color coding of fixture wires (see fig. 2 on page 18).
8. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against
black outlet box wire. Do not twist wires.
9. Fit wire connector (M from fig. 1) overwires and twist until there is a firm connection. If
wire connector (M) easily comes off, reattach and check again for a firm connection.
10. Repeat steps 8 and 9 with the white (group B from fig. 2) fixture wires and outlet box wires.
11. Partially thread green grounding screw (N) into side hole (O) on mounting bar (B)
(see fig.1.)
12. Wrap ground wire from fixture around green grounding screw (N), leaving enough excess
wire to then connect ground wire and outlet box wire with wire connector.
13. Tighten green grounding screw (N). Do not over tighten.
14. Tuck wires inside outlet box (C).
FLUSH MOUNT MOUNTING AND WIRING INSTRUCTIONS
FLUSH FIXTURE ASSEMBLY INSTRUCTIONS
1. Raise canopy (L) to ceiling, allowing mounting screws (A) to protrude through openings in
canopy (L) and secure with cap nuts.
2. Install lamp (s). Do not exceed recommended wattage.
3. Turn power back on at circuit box.
20 pg_W-076_EFS 11/12/04 10:33 AM Page 7