TROUBLESHOOTING
12
226 306627 OpManual for HDHP-Series Hot Plates
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Pilot will not light Gas supply off Check main / unit gas valves
Air in lines Turn pilot valve on. Attempt to
light pilot every 15 sec.
Pilot valve not on Turn pilot valve on / adjust
Burners won’t light Gas supply off Check main / unit gas valves
Air in lines Turn gas valve on. Attempt to
light pilot every 15 sec.
Pilot valve not lit Turn off gas - allow unit to
vent for 5 minutes. Turn gas
back on and light pilot
Front or rear burner
won’t light
Control not on Turn temperature control to ON
Set to desired setting when lit
Water in burner Remove burner and dry
thoroughly
Damaged temperature control,
Burner or other internal
component
Contact Authorized Wells
Service Agency for repairs
Temperature control not set Adjust for desired temperature
Shutter or nozzle out of
adjustment
Contact qualified technician for
adjustment
Damaged temperature control,
burner or other internal
component
Contact Authorized Wells
Service Agency for repairs
NOTE: There are no user
serviceable components in the
burner assemblies or in the con-
trol valves. In all cases of dam-
age or malfunction,
contact your Authorized Wells
Service Agency for repairs.
Burner not hot enough