Weil-McLain LGB Boiler User Manual


 
21Part Number 550-110-592/1000
FOR YOUR SAFETY READ BEFORE OPERATING
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO THE APPLIANCE
Do not try to light any appliance.
Do not touch any electric switch; do not use
any phone in your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
WHAT TO DO IF YOU SMELL GAS
A. This appliance does not have a pilot. It is equipped
with an ignition device which automatically lights
the burner.
Do not try to light the burner by hand.
B. Before
OPERATING, smell all around the
appliance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle on the floor. See below.
C. Use only your hand to turn the gas control knob. Never use
tools. If the knob will not turn by hand, don't try to repair it,
call a qualified service technician. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
1. STOP! Read the safety information above on this label.
2. Set the thermostat to lowest setting.
3. Turn off all electrical power to the appliance.
4. Remove jacket front panel.
5. This appliance is equipped with an ignition device which automatically lights the burner.
Do not try to light the burner by hand.
6. Turn Gas control knob clockwise to OFF.
7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas,
go to the next step.
8. Turn Gas control knob counterclockwise to ON.
9. Turn on all electric power to the appliance.
10. Set thermostat to desired setting.
11. If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO
APPLIANCE
" below and call your service technician or gas supplier.
12. Replace jacket front panel.
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to
be performed.
26070
Position indicator
(shown in "ON" position)
White-Rodgers
36C Gas valve
White-Rodgers
36E Gas valve
Honeywell
VR8204 or
VR8304
Gas valve
Position indicator
(shown in "ON" position)
Gas control knob
Gas control knob
Gas control knob
Position indicator
(shown in "ON" position)
Operating instructions
Spark-ignited pilot
CGi, CGs
Gas valve Honeywell VR8204/VR8304, White-Rodgers 36C and 36E
3. Remove jacket front panel.
4. Turn Gas control knob clockwise to OFF. Do not
force.
5. Replace jacket front panel.