Weil-McLain 800060000-Brn-PO Rie BF5 Burner User Manual


 
3398
2
GB
TECHNICAL DATA
SPECIFICATIONS
BURNER AND MOUNTING FLANGE DIMENSIONS
BURNER COMPONENTS IDENTIFICATION
Fuel No. 2 Fuel Oil
BF3 Firing rate - Effective Output
0.50 to 0.95 US GPH - 70,000 to 133,000 BTU/h
BF5 Firing rate - Effective Output
0.75 to 1.65 US GPH - 105,000 to 231,000 BTU/h
Voltage (single phase) 120V 60Hz (+ 10% - 15%)
BF3 Absorbed electrical power
192 Watts
BF5 Absorbed electrical power
204 Watts
Motor (rated) 3250 rpm Run Current 2.2 AMP
Capacitor 12.5 Microfarads 260V
Pump pressure 100 to 200 PSI
Primary control RIELLO 530 SE/C
Ignition transformer 8kV 16mA
Model A B C D E F
BF3
Inches 9 13/16 11 1/4 7 1/2 3 1/2 4 5/8 8 21/32
mm 249 286 193 89 117 220
BF5
Inches 9 13/16 11 1/2 7 1/2 3 1/2 6 5/16 6 13/16
mm 249 292 193 89 160 173
5
9
/
16
”-141mm
7
9
/
16
” - 192 mm
8
1
/
2
” - 216 mm
3
9
/
16
90 mm
6
0
°
4
5
°
3
0
°
BURNER COMPONENTS
1 Lockout indicator lamp and reset button
2 Primary control
3 Primary control sub-base
4 Pump pressure regulator
5 Post purge timer
6 Air adjustment
7 Capacitor
8 Combustion head
9 Mounting gasket
10 Universal mounting flange
11 Turbolator adjustment screw
12 Coil
13 Bleeder and pressure gauge port
14 Return fuel line port
15 Inlet fuel line port
16 Pump
17 Air pressure switch
D7516
D7515
B
A
EF
C
D
03
D8174
1
2
3
4
5
6
7
15
8 9 10
11
12
1314
16
17