4
LOCATING YOUR BUILT-IN SIDE BURNER
When determining a suitable location for your Built-In Side Burner installation,
give attention to concerns such as exposure to wind, proximity to traffi c paths,
and keeping any gas supply lines as short as possible. Never locate the Sum-
mit
®
Built-In Side Burner in a garage, breezeway, shed, under an unprotected
overhang, or other enclosed area. Locate the Side Burner and structure so
there is enough room to safely evacuate the area in case of a fi re.
CLEARANCE FROM COMBUSTIBLE SURFACES OR
STRUCTURES
ƽ WARNING: Clearance from the outside walls of the
sides and back of the LP Tank Cabinet must be a minimum
of 24 inches any surface. Refer to “Typical Gas Supply
Installation” before starting installation.
ƽ WARNING: The structure, “island” counter tops and
adjacent work areas for the LP Tank Cabinet installation
must be built from noncombustible materials only.
NOTE: If you have questions on what materials are considered
noncombustible, contact you local building supplier or fi re department.
Any Surface
Any Surface
24 inches Any Surface
24 inches
24 inches
Note: For a countertop
treatment: Recommended
3/4 inch overhang. Notch
front edge for frame to
fully slide in.
Side
Burner
24 inches min.
for lid clearance
BUILT-IN SRUCTURE CUTOUT DIMENSIONS
All dimensions are to fi nished surfaces.
ƽWARNING: All counter top fi nished surfaces must be
constructed of a noncombustible material.
GAS INSTRUCTIONS
Side Burner
Cut out Dimensions Tolerances
A
10
1
2
"+
1
/
4
" -
1
/
4
"
B
3
3
/
4
"+
1
/
4
" -
1
/
4
"
C
16
1
/
4
"+
1
/
4
" -
1
/
4
"