12
LIGHTING THE SIDE BURNER.
1) Open the side burner lid.
2) Check that the side burner valve is turned OFF. (Push knob in and turn
clockwise to ensure that it in the off position.)
ƽ WARNING: The burner control knob must be in the
OFF position before turning on the liquid propane
cylinder valve. If it is not in the OFF position, when
you turn on the LP cylinder valve, the “excess gas
fl ow control” feature will activate, limiting the fl ow
of gas from the LP cylinder. If this should occur, turn
OFF the LP tank valve and burner control knobs. Then
start over.
LIQUID PROPANE (LP) CYLINDER(S)
• The joint where the hose connects to the LP cylinder must be leak tested
each time the LP cylinder is reconnected. For example, test each time the
LP cylinder is refi lled.
• Be sure the regulator is mounted with the small vent hole pointed
downward so that it will not collect water. This vent should be free of dirt,
grease, bugs etc.
• The LP cylinder and connections supplied with your Weber
®
gas barbecue
have been designed and tested to meet government, American Gas
Association, and Underwriters Laboratories requirements.
DOT 4BA240
00/02
(1)
(2)
OPERATING
If you have questions about spare LP cylinders contact
Customer Service at 1-800-446-1071.
• All LP tank supply systems must include a collar to protect the cylinder
valve.
• The LP cylinder must be a 20-lb. size (18 1/4 inches high, 12 1/4 inches in
diameter).
• The cylinder should be constructed and marked in accordance with
the Specifi cations for LP - Gas Cylinders of the U.S. Department of
Transportation (D.O.T.) or the National Standard of Canada,
CAN/CSA-B339, Cylinders, Spheres and Tubes or Transportation of
Dangerous Goods; and Commission, as applicable.
SIDE BURNER LIGHTING INSTRUCTIONS
ƽ DANGER
Failure to open the lid while igniting the side
burner, or not waiting 5 minutes to allow the gas
to clear if the side burner does not light, may
result in an explosive fl ame-up which can cause
serious bodily injury or death.
3) Turn the LP tank valve on (turn counter-clockwise).
4) Push in and turn the side burner control valve to START/HI.
5) Push igniter button and hold until burner ignites. You will hear the
igniter sparking.
ƽ CAUTION: Side burner fl ame may be diffi cult to see
on a bright sunny day.
ƽ WARNING: If the side burner does not light:
1) Turn OFF the side burner control valve.
2) Wait 5 minutes to let the gas clear before you try
again or try to light with a match.
TO EXTINGUISH
Push down and turn each burner control knob clockwise to the OFF
position. Turn gas supply OFF at the source.