Wayne-Dalton 342295 Garage Door Opener User Manual


 
2
Emergency
Disconnect
Label
Motor
operated
position
Manual
operated
position
Set screw
Disconnect
cable
Disconnect
handle
Full upper
position
Emergency disconnect label
Cable stop/pivot
Tools Needed:
#2 Phillips
Screwdriver
Wire Cutters
With the Handle in the up position as shown, rotate the Cable
Stop/Pivot so the set screw is facing you. Route the
Disconnect Cable behind the Handle and through the hole in
the Cable Stop/Pivot (with the Set Screw facing you).
Position Handle in the full upper position and remove all cable
slack between the Opener and the Handle Bracket. Pull the
Disconnect Cable only enough to remove the Cable slack. Too
much tension could disconnect opener and cause failure to
reconnect.
Tighten the set screw using Phillips screwdriver to securely
clamp the disconnect cable. Trim off excess cable, as close as
you can, beyond bottom of the Cable Stop/Pivot.
Apply Emergency Disconnect Label next to the Disconnect
Handle Bracket. Use mechanical fasteners if adhesive will not
adhere.
Attaching Disconnect Cable
3
Tools Needed:
None
Using the Emergency Disconnect, pull Disconnect
Handle downwards and place it in the manual door
operated position (disconnects door opener from door).
Return handle to the up position to re-connect opener to
the door.
Disconnect Handle Usage
4
Disconnect
cable