Wayne ISP40 Plumbing Product User Manual


 
Operating Instructions and Parts Manual
8
Model ISP40
Limited Warranty
For two years from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the
original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be
defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to
provide the model and serial number when exercising this warranty. All transportation charges on Products or parts
submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect,
improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE. THIS IS THE
EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENS-
ES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of
incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you
specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its
suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or
revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of
substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such
damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST
send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return
authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________
INSTALLATION DATE_____________
ATTACH YOUR RECEIPT HERE
www.waynepumps.com
Please completely read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage! Retain instructions for future reference.
Description
The AC/DC Sump Pump System
includes a submersible sump pump
and a Power Supply/Battery Charger
(PS/BC). Backup power is supplied by
two 12 volt batteries (not included).
The system is designed for home sump
applications. When an electrical power
outage occurs, the PS/BC automatically
switches the sump pump to battery
power so it will continue to pump
water. Using LED’s (Light Emitting
Diodes), the PS/BC also alerts you to
potential problems.
Safety Guidelines
This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates a
potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
Do not
use to
pump flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in a flammable and/or explosive
atmosphere. Personal injury and/or
property damage could result. Only use
pump to pump clear water.
!
DANGER
NOTICE
!
CAUTION
!
WARNING
!
DANGER
Model ISP40
351905-001 3/07
This pump is not
designed to handle
salt water, brine, laundry discharge,
water softener, sewage, graywater or
any other application which may
contain caustic chemicals and/or
foreign materials. Pump damage could
occur if used in these applications and
will void warranty.
All wiring must be
performed by a
qualified electrician.
!
WARNING
NOTICE
If the
basement
has water or moisture on the
floor, do not walk on wet
area until all power is turned
off. If the shutoff box is in the
basement, call an electrician. Remove
pump and either repair or replace.
Failure to follow this warning could
result in fatal electrical shock.
!
DANGER
AC/DC Sump Pump System
© 2007 Wayne Water Systems
Operating Instructions and Parts Manual
Pump Specifications
Pump Construction
Motor housing, volute, filter cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron
Impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass-filled Ryton
®
Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .410 Stainless Steel
Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1
/
2
” NPT
Float switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-position
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Stainless Steel
Power supply requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60 Hz
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brushless Integral Processor
Normal water removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 GPM @ 10 Feet
Liquid temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°F to 120°F
Circuit requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 amps AC (min)
Pump Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1
/
2
” high x 9
3
/
4
” base
Pump starts at (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12” Water Level
Pump stops at (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6” Water Level
Stainless Steel
Filter
Power
Supply/
Battery
Charger
(PS/BC)
Battery
Cables
Pump
Power Cord
Power
Supply/Battery
Charger (PS/BC)
Power Cord
Figure 1 – System Components
Battery Jumper Wire
Record Serial Number here. (Serial
Number is found on Pump Housing)
Pump Fuse
AC Circuit
Breaker
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
Pump
For parts, product & service information
visit www.waynewatersystems.com