Waterford Appliances E65-LP1 Stove User Manual


 
26
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove
REDUCTION KIT TO
LOWER BTU RATING
FOR E65-1 GAS STOVE
3) Open the front door. Open the right side
door and there is a cutout in the heat shield
through which can be seen a wing nut
threaded on to a stud attached to the front
door. Loosen this nut by turning it counter-
clockwise.
Natural Gas Conversion Kit 260-920
Contains:
Qty.Part # Description
1 904-593 Burner Orifice #40
(Natural Gas)
1 908-365 Decal "Converted to
27,000 Btu"
1 908-363 Instruction Sheet
Propane Conversion Kit 260-922
Contains:
Qty.Part # Description
1 904-390 Burner Orifice #52 (Propane)
1 908-365 Decal "Converted to
29,000 Btu"
1 908-363 Instruction Sheet
1) Shut off the gas supply.
2) Open the valve door and remove the con-
trol panel.
The wing nut that holds the front door is
accessible through the cut-out in the right
side heat shield.
E63/E65 Conversion Decal: 908-175
Burner Orifice
9) Unscrew the pilot orifice with the allen key
and replace with the LP pilot orifice in the kit.
INSTALLATION
6) Remove and discard the 3 pressure regu-
lator mounting screws (A), pressure reg-
ulator tower (B) and diaphragm (C).
7) Insure that the rubber gasket (D) is properly
positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.
8) Pull off the pilot cap to expose the pilot
orifice.
10)Remove burner orifice with a 1/2" wrench
and discard. Use a wrench to hold on to the
elbow behind the orifice.
11)Reinstall new burner orifice LP stamped
#50 and tighten.
12)Reverse steps 4) to 2).
13)Attach the Conversion label "This unit has
been converted to Propane" on top of the
Serial # decal. E63/E65: Part #175
14)Replace yellow "Natural Gas" label with red
"Propane" label
15)Check for gas leaks.
16)Check inlet and outlet pressures.
17)Check operation of flame control.
18)Check for proper flame appearance and
glow on logs.
THIS CONVERSION MUST
BE DONE BY A
QUALIFIED GAS FITTER IF
IN DOUBT DO NOT DO
THIS CONVERSION !!