Vulcan-Hart VHL2E Carpet Cleaner User Manual


 
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specications without notice.
F-32573 (8-04)
VHLE SERIES
SUPER STEAMER, ELECTRIC BOILER
TWO OR THREE COMPARTMENT MODELS
SERVICE CONNECTIONS:
ELECTRICAL CONNECTION: Junction box for electrical con-
nection for boiler heat and controls.
DRAIN: Condenser box, compartment and boiler, 1
1
/2" NPT.
(Provide an open air type drain within 12" of condenser box and
for best results at a distance so that steam vapors will not enter
the steamer from underneath the control area. Do not connect
solidly to any drain connections.)
COLD WATER CONNECTION:
1
/2" NPT for boiler feed. Inlet
water pressure between 20 and 80 psi.
COLD WATER CONNECTION:
1
/2" NPT for condensate box.
Inlet water pressure between 20 and 80 psi.
WATER: For swing faucet, (single) (dual) temperature
1
/4" IPS
tailpiece.
STEAM TAKE-OFF CONNECTION:
3
/4" NPT.
NOTE:
• Dimensionswhichlocatetheaboveconnectionshaveatoleranceof
+ or -3" (+ or -75 mm).
• Installationofbackowpreventers,vacuumbreakersandotherspecic
code requirements is the responsibility of the owner and installer. It is
the responsibility of the owner and installer to comply with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimitedtempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.
• Thisapplianceismanufacturedforcommercialinstallationonlyandis
not intended for home use.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:
SUPPLY PRESSURE 20 - 60 psig
HARDNESS* less than 3 grains
SILICA less than 13 ppm
TOTAL CHLORIDE less than 4.0 ppm
pH RANGE 7-8
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.
PAN CAPACITIES (Per compartment)
MODEL 1" deep 2
1
/2" deep 4" deep 18"x26"x1"
VHLE 16 8 6 6
Total
Conn.
KW
NOMINAL AMPS PER LINE
Three Phase Single Phase
208 240 480 380/50/60, 4 wire 208 240
24 66.0 58 29 31 116 100
36 99.9 86.6 43.3 46 N/A N/A
42 118 N/A N/A N/A N/A N/A
48 N/A 116 58 62 N/A N/A