Page 6 19400-3-0406
Figure 1
Dim BVD34 BVD36 BVP42
A
37"
940mm
39"
990mm
43"
1092mm
B
34"
864 mm
36"
914mm
40"
1,016mm
C
22 7/8"
581mm
24 7/8"
632mm
24 7/8"
632mm
D
35 5/8"
905 mm
37 5/8"
956 mm
37 5/8"
956 mm
E
32 3/4"
832mm
34 3/4"
883 mm
34 3/4"
883 mm
F
14 7/8"
378mm
18 3/8
467mm
18 3/8"
467mm
G
6 3/8"
162mm
6 3/8"
162mm
6 3/8"
162mm
H
5 7/8"
149mm
8 3/8"
213mm
6 3/8"
162mm
I
24 1/2"
622mm
22 1/2"
572mm
26 1/2"
673mm
J
12 1/4"
311mm
11 1/4"
286mm
13 1/4"
337mm
K
1 1/4"
32mm
1 1/4"
32mm
1 1/4"
32mm
L
31 3/4"
807mm
33 3/4"
857mm
33 3/4"
857mm
M
32 11/16"
830mm
34 11/16"
881mm
34 11/16"
881mm
N
2 1/16"
53mm
2 1/16"
53mm
2 1/16"
53mm
O
5 5/8"
143mm
5 5/8"
143mm
5 5/8"
143mm
P
4 7/8"
124mm
4 7/8"
124mm
4 7/8"
124mm
Remote Control Options &
Accessories
Description
FRBC MILLIVOLT BATTERY REMOTE ON/OFF
FREC DIRECT IGNITION/MILLIVOLT 120V ON/OFF REMOTE
FWS-1 DIRECT IGNITION/MILLIVOLT WALL SWITCH
BVD34FP BVD36FP BVP42FP
Input Btu/hr Maximum 21,000 25,000 30,000
KWH (Maximum) 6.2 7.3 8.8
B-Vent Size 4" Diameter 6" Diameter 6" Diameter
NAT. (Standard)
Orifice
#44 (.086)
P-252
#42 (.0935)
P-286
#37 (.104)
P-213
Air Shutter Opening 1/8" (3.2mm) 1/8"(3.2mm) 1/8" (3.2mm)
*LP (Conversion Kit Required)
Orifice
1.35mm
P-289
1.45 mm
P-208
1.65mm
P-250
Air Shutter Opening 5/16" (7.9mm) 5/16" (7.9mm) Full Open
Height without standoff 32 3/4"(832mm) 34 3/4"(883mm) 34 3/4"(883mm)
Width 37" (940mm) 39" (990mm) 43" (1,092mm)
Depth 14 7/8" (378mm) 18 3/8" (467mm) 18 3/8" (467mm)
Gas Inlet Shutoff Valve (Pipe) 1/2 NPT 1/2 NPT 1/2NPT
NOTE: Air shutter
settings are factory
minimum settings. Some
venting configurations
may require minor air
shutter adjustments for
optimum performance.
RIGHTSIDEVIEW
J
H
GASCONTROLSBEHINDLOWER
LOUVERORUNDERSLIDING
HEAR
THACCESSDOOR
K
K
L
M
M
G
O
N
P
G
*NOTE: LP Conversion kits are included on the 120v. direct ignition model fireplaces. For millivolt models, use kit
#19160 for BVD34FP Series, kit #19161 for BVD36FP Series, and kit #19162 for BVP42FP Series.
SPECIFICATIONS
FIREPLACE DIMENSIONS