Vornado ULTRA1 Humidifier User Manual


 
10 English English
11
To Disinfect:
Place Mist Outlet back into Water Tank.
Fill Base and Water Tank with a mixture of water and chlorine
bleach - mixed at a ratio of one (1) teaspoon of chlorine bleach
per 1 gallon of water (D). Do not overfill, discard unused portion.
Solution should remain in Base and Water Tank for 20 minutes to
fully disinfect.
Rinse with water until bleach smell is gone. Dry with clean cloth or
paper towel.
Reinstall all components. Components must be securely in place
for unit to function properly.
Fill Base and Water Tank with a mixture of water and white vinegar -
mixed at a ratio of one (1) 8 oz. cup of undiluted white vinegar per 1
gallon of water (B). Do not overfill, discard unused portion. Solution
should remain in Base and Water Tank for 20 minutes to dissolve any
residue.
Empty after 20 minutes and clean Mist Outlet and all interior surfaces
of Base and Water Tank with soft brush (C). Use Cleaning Brush,
stored in Base of unit to clean hard to reach areas. Dampen soft
cloth with undiluted white vinegar and wipe down to remove scale.
Rinse thoroughly with clean warm water before disinfecting.
Cleaning Instructions
Proper cleaning of your Ultrasonic Vortex Humidifier is essential to the
air quality and performance of your unit. The frequency in which your
Humidifier will need to be cleaned will vary, depending on use, water
hardness, and outside environmental factors. It is recommended,
assuming average use, to thoroughly clean the unit several times
throughout the season, or when algae, mineral deposits or other
particles begin to form. To clean your Humidifier, follow these
instructions:
Turn the Humidifier Off and unplug. Do not submerge into water.
Remove Mist Outlet by grasping base of Outlet and pulling up (A).
Empty water from Base and Water Tank. (See FILLING WATER
TANK for instructions). Place Mist Outlet inside Water Tank to
clean both components at the same time.
Note: Do not operate the unit during cleaning.
Mineral Cartridge Replacement
The Mineral Cartridge removes minerals from the water thereby
softening the water and reducing harmful mineral buildup on the
Transducer.
When to Replace: Many factors affect the frequency in which
the Cartridge will need to be replaced - including amount of
use, water hardness, and outside environmental factors. For
Cleaning and Maintenance
1.
2.
3.
4.
heavy use, using the unit continuously, we recommend replacing the
Cartridge approximately once a month. For lighter use, using the
unit intermittently, we recommend replacing the Cartridge every two
months.
The Cartridge will need to be replaced earlier if white powder residue
accumulates around the device. If the water used in the humidifier has
been treated by a decalcification system, the salt from the treatment can
show up as white dust also.
How to Replace:
Remove Water Tank (See FILLING WATER TANK for instructions)
Unscrew Cap.
Unscrew Mineral Cartridge from Cap (A). Discard Cartridge.
Install new Cartridge onto Cap.
If continuing use of Humidifier, fill Water Tank and reinstall Cap.
Replace Tank back into unit. Your Humidifier is now ready for use.
Note: the unit may take several minutes to create mist with the initial
use of a new Mineral Cartridge.
If storing unit, empty Water Tank and reinstall Cap. Replace Tank
back into unit. See STORAGE for instructions.
Cleaning and Maintenance
A
8 oz.
White
Vinegar
+
1 gal.
Water
C
1.
2.
3.
4.
B
1.
2.
3.
4.
5.
6.
D
1 tsp.
Chlorine
Bleach
+
1 gal.
Water
View cartridge
replacement tutorial on
your mobile device.
MINERAL CARTRIDGE
MINERAL CARTRIDGE