BEFORE MACHINE START-UP
PRE-OPERATION CHECKS
Sweep or dust mop the surface to be cleaned.
Check battery meter to make sure batteries are fully charged. (see BATTERY CHARGING)
Check that squeegee is properly installed.
Check that brush / pad is properly installed.
1.
2.
3.
4.
WARNING!
Do not put any flammable materials into solution tank. This can cause an explosion or a fire. Only use reco-
mmended cleaning chemicals. Contact your janitorial supply distributor for recommendations on proper ch-
emicals.
INSTALLING PAD DRIVER OR BRUSH
The Fang 20-EU / Fang 20T-EU can be filled in two different locations:
a. Front fill area for use with a hose or a bucket.
b. Rear fill area for use with a hose only.
1.
NOTE
Remove the squeegee assembly prior to tilting the machine backwards. It makes the process faster and easier.
Determine which fill area you would like to use to fill the machine with water.
Fill solution tank with up to 48 liters of water. (water temperature should not exceed 40° C) The clear tube in the back left
of the machine has gallon markers to help determine the water level in the solution tank.
2.
3.
WARNING!
Do not keep the machine tilted back for a long time. This could cause battery acid to leak from the batteries.
If using a pad driver, first attach the appropriate pad to the pad driver surface.
Mount the pad driver or brush to the drive motor hub by lining up the three studs with the three holes in the drive motor hub.
Once in the holes, rotate the driver toward the spring clip to lock driver into place.
4.
5.
MOUNTING THE SQUEEGEE
Pull back on the squeegee lift lever to raise the squeegee bracket up.
Loosen the two knobs on the squeegee and slide the squeegee into the slots at the rear of the squeegee bracket. (the wheels
on the squeegee point to the back)
1.
2.
Tighten the knobs securely.3.
FILLING THE SOLUTION TANK
Ensure that the machine is turned off.
Lower brush head assembly to the floor by stepping on the foot pedal and pushing pedal forward.
Tilt the machine backward to access the drive motor hub.
1.
2.
3.
NOTE
If you are filling the solution tank with a bucket, make sure the bucket is clean. This will prevent debris from clogging
the lines or solenoid.