OUTDOOR—COOKING
Built-In Gas Side Burner, 24”W. Rangetop,
Wok/Cooker, & TruSear
Infrared Grillers
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
Dimensions & Specifications
CUTOUT DIMENSIONS
VGSB152T/VGIB151T VGRT244T/VGWT241T/VGIB242T
VGSB152T VGRT244T VGWT241T VGIB151T VGIB242T
Cutout width 14” (35.6 cm) 24-3/4” (62.9 cm) 24-3/4” (62.9 cm) 14” (35.6 cm) 24-3/4” (62.9 cm)
Cutout height 10-1/4” (26.0 cm)
Cutout depth 27-1/2” (69.9 cm) 27-1/2” (69.9 cm) 27-3/8”(69.5 cm) min. to 27-1/2” (69.9 cm) 27-1/2” (69.9 cm)
27-7/8” (70.8 cm) max.
15”W. SIDEBURNERS & GRILLERS
1. Maintain a minimum of 6” (15.2 cm)
from the sides of the side burners
(above the cooking surface) to
adjacent vertical combustible
construction. Do not install under
overhead, unprotected combustible
construction.
2. Allow at least 6” side clearance to
non-combustible construction above
the cooking surface for counter space.
3. When choosing a suitable location,
consider factors such as wind
exposure, proximity to traffic paths,
keeping gas supply lines as short as
possible. Install only in a well-
ventilated area. Never install in a
building, garage, breezeway, shed, or
other such fully enclosed areas.
24”W. RANGETOP/WOK/GRILLER
PROXIMITY TO CABINET INSTALLATION
The unit may be installed directly
adjacent to the existing base cabinets.
The side trim must be 3/8” (0.95 cm)
above the adjacent base cabinet
countertop. There is a 0” side and rear
clearance to non-combustible surfaces.
The unit cannot be installed directly
adjacent to combustible sidewalls. There
must be a minimum of 6” (15.2 cm) side
and rear clearance from the unit to such
combustible surfaces. This unit cannot be
placed under an overhead which is
unprotected and combustible.