Vicks V3600 Humidifier User Manual


 
Wicking Filter Maintenance
Wicking Filter performance will diminish depending on the mineral content of the
water and the amount of airborne dust in the environment.
IMPORTANT: CHECK WICKING FILTER REGULARLY. Any of the following conditions indicate
that it is time to replace the Wicking Filter.
A buildup of impurities and minerals on the Wicking Filter (evidenced by discoloration of
the Wicking Filter)
An appreciable decrease in Humidier output
The top of the Wicking Filter is not moist to the touch
The Wicking Filter has large holes or tears
The Wicking Filter should be replaced at least one or two times during the season, depending
on usage, mineral content of the water and the environment. We encourage you to only use a
Kaz Model WF2 Replacement Wicking Filter. The use of other Wicking Filters may lead to
substandard performance.
Replacement Filters
WF2 Wicking Filters are generally available where you purchased your Humidier. If you are
unable to locate replacement lters at your local retailer, they may be ordered directly from Kaz.
To Order:
By Phone
Call toll-free by dialing 1-800-477-0457. Please have your credit card handy for payment. We
accept Visa and Master Card. Minimum credit card order is $10.00.
By Fax
Fax your order to Kaz Consumer Service Orders at 1-518-828-2015. Please clearly print your
name, mailing address and products ordered. Be sure to specify Visa or Master Card, card
number and expiration date, and sign your order. Minimum credit card order is $10.00.
By Mail
Mail your order to Kaz Consumer Service Orders, P.O. Box 544, Hudson, NY 12534. Please
clearly print your name, mailing address, and products ordered. Enclose check or money order
(no cash, please).
Via The Internet www.kazstore.com
End of Season Maintenance or When
Humidier Will Not Be In Use For
At Least One Week
1. Clean and dry the Humidier thoroughly per the Weekly Maintenance instructions above.
2. Let Humidier dry completely before storing. Do not store with water inside the Base.
3. Remove Fill Cap. Do not store Humidier with Fill Cap on.
4. At end of season, remove and throw away the Wicking Filter. Never leave a used Wicking
Filter in the Humidier during storage.
5. Store in a cool dry location.
6. Order your new Kaz Replacement Wicking Filter now so that it will be available for use
next season.
Troubleshooting
If the unit does not operate:
Check that polarized plug is fully inserted into wall outlet.
Check airflow. Are there any obstructions preventing airflow?
The motor contains a temperature-limiting fuse. If the motor overheats, the fuse will trip
and shut off the motor. Unplug the unit and contact our Consumer Service Department.
Do not attempt to repair the motor yourself.
If you do not obtain enough humidity:
The moisture output from an evaporative Humidier is invisible. It is operating properly
if water level goes down during usage, even when you cannot see the vapor.
Check the Wicking Filter. Replace the Filter if it is clogged, torn or discolored.
Check the water level. Relling may be required.
Adjust the humidistat to allow a higher humidity level.
If you are obtaining too much humidity:
If room air is excessively humid (greater than 50% relative humidity), do not use the
Humidier. Excessive humidity is indicated by condensation on cold surfaces or walls in
the room. Adjust the humidistat to restrict to a lower humidity level.
If water leakage occurs:
Make sure unit is unplugged from wall outlet.
Remove Tank from Base and check Fill Cap. Make sure the Cap Gasket (O-Ring) is
properly positioned in the cap and the Spring Valve operates freely. If leakage still
occurs contact our Consumer Service Department.
If Fill Cap is too tight:
Lightly lubricate the Cap Gasket (O-Ring) with petroleum jelly.