Velodyne Acoustics HDL-64E S2 Home Security System User Manual


 
[ 9 ]
HDL-64E S2 and S2.1 User’s Manual

Available commands
The following run-time commands are available with the sensor:
Command Description Parameters
#HDLRPMnnnn$ Set spin rate from 300 to 1200 RPM nnnn is an integer between 0300 and 1200
n flash memory (default is 600 RPM)
#HDLRPNnnnn$ Set spin rate from 300 to 1200 RPM nnnn is an integer between 0300 and 1200
in RAM (default is 600 RPM)
#HDLIPAssssssssssssdddddddddddd$ Change source and/or destination • ssssssssssss is the source 12-digit IP address
IP address • dddddddddddd is the destination 12-digit
IP address
#HDLFOVsssnnn$ Change horizontal Field of View (HFOV) • sss = starting angle in degrees; sss is an integer
between 000 and 360
• nnn = ending angle in degrees; nnn is an
integer between 000 and 360
You can also upload calibration data from db.xml into flash memory and use GPS time synchronization.
.