Vanguard Heating VP1600D Gas Heater User Manual


 
24
101823
GRH/OV 007GOOD PILOT/LP
Thermocouple
Pilot Burner
Figure 23 - Correct Pilot Flame Pattern
Thermocouple
GRH/OV 008BAD PILOT/LP
Pilot Burner
Figure 24 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 24
• turn heater off (see To TurnOff Gas to Appliance, page 20 [models
VP1600ITA and VP2200ITA] or page 24 [models VP1600D and VP2600D])
• see Troubleshooting, pages 26 through 29
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
Clockwise
to the OFF position.
2. Turn off all electric power to the appliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
1. Turn control knob clockwise
Clockwise
to the PILOT position.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, pages 21 and 22.
2. With control knob pressed in, strike match. Hold match to pilot until pilot
lights.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
OPERATING
HEATER
Models VP1600D
and VP2600D
Continued
INSPECTING
BURNER
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.