3
105274
OWNER’S MANUAL
AUTO
MAN
OFF
STATUS
ONLO
HI
TEMP
PRODUCT
IDENTIFICATION
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANS Z223.1, also known as
NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs
are required, thermostat operation is not
permitted.
UNPACKING
CAUTION: Do not remove the
metal Data Plates from the grate
assembly. The Data Plates contain
important product information.
1. Remove logs and heater base assem-
bly from carton.
Note:
Do not pick up
heater base assembly by the burner.
This could damage heater. Always
handle base assembly by grate.
2. Remove all protective packaging ap-
plied to logs and heater for shipment.
3. Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.
Figure 1 - Product Identification
Flame-Max
®
Golden Oak Logs
Control Knob
Piezo
Ignitor
One Piece
Log Set
Base Assembly
Optional
Remote
Control
Flame
Adjustment
Knob
Optional Selector
Switch
PRODUCT
FEATURES
OPERATION
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
realistic, dancing yellow flames. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANS Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free
heaters. This heater may also be operated as
a vented decorative (ANS Z21.60) product
by opening the flue damper (non-thermostat
operation only).
SAFETY PILOT
This heater has a pilot with an Oxygen
Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
REMOTE CONTROL
ACCESSORIES
There are four optional remote controls that
can be purchased separately for this log
heater:
• wall switch
• wall thermostat
• hand held ON/OFF remote
• hand held thermostat remote
See Accessories, page 25.
The wall thermostat or hand-held thermo-
stat may not be used where vented decora-
tive listing is required.