Locate the blower switch by opening lower
louver on fireplace. Blower switch is lo-
cated at lower left inside louver door.
This thermostat-controlled blower has a
variable speed control with an ON/OFF
switch. The blower will start when the
thermostat senses a sufficient increase in
firebox temperature.
Note:
It is safe to operate fireplace with
blower turned off. However, the blower helps
distribute heated air from the fireplace.
MODEL VSGF28PV
Blower Kit Model GA3750 Series
This optional non-thermostat blower kit
features a variable control which allows
you to select the speed you desire. After
about 15 minutes, turn the blower on to
deliver heated air at the top louvers. Fol-
low the installation instructions on pages
8 and 9 of this manual.
IMPORTANT:
Light your gas appliance
with the blower off.
Note:
Periodically check the louvers of
the firebox and remove any dust, dirt, or
other obstructions.
BLOWER
OPERATION
WARNING: This fireplace has
a three-prong, grounded electri-
cal plug. This plug helps protect
you against electrical shock. Only
connect plug to a properly
grounded, three-prong recep-
tacle. Do not cut or remove the
grounding prong from this plug.
MODEL VSGF28PTC
Figure 31 - Pilot
6. Continue pressing control knob in.
Press and release ignitor button. This
will light pilot. The pilot is attached to
the front burner. If needed, keep press-
ing ignitor button until pilot lights.
Note
: If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure, column 2.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7.
If control knob does not pop out
when released, contact a qualified
service person or gas supplier for
repairs.
8. Slightly depress and turn control
knob couterclockwise to the
high position. Both burners should
light. Set control knob to either
HIGH or LOW.
OPERATING
FIREPLACE
Continued
TO TURN OFF GAS
TO APPLIANCE
WARNING: Do not operate
heater between locked positions.
CAUTION: Do not try to adjust
heating levels by using the equip-
ment shutoff valve.
The variable control valve can be set to any
heat setting and flame height desired, by
simply turning the control knob until that
setting is attained. Even the lowest setting
provides realistic flames and glowing em-
bers from two burners. Selecting higher
settings produces greater heat output. This
results in increased heating comfort.
Shutting Off Fireplace
1. Turn control knob clockwise
Clockwise
to the HIGH position.
2. Slightly depress control knob and
turn clockwise
Clockwise
to the PILOT
position.
3. Slightly depress control knob and
turn clockwise
Clockwise
to the OFF
position.
Shutting Off Burners Only (pilot
stays lit)
1. Turn control knob clockwise
Clockwise
to the HIGH position.
2. Press in and turn clockwise
Clockwise
to the PILOT position.
VARIABLE CONTROL
OPERATION
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Light-
ing Instructions, page 15.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, column 1.
Ignitor
Electrode
Pilot Burner