Vanguard Heating NLFB32NC Indoor Fireplace User Manual


 
www.desatech.com
105604-01J 11
7. Plug in blower power cord.
a. If your firebox is installed as a freestanding
unit, determine whether the power cord
will exit the left side or the right side of the
firebox. Install 1 plastic bushing provided
into the 1
1
/
2
" hole in the floor support on
the exit side. Install the second plastic
bushing provided into the 1
1
/
2
" hole in the
outer casing through which the power cord
will exit (see Figure 11). Route power cord
through both plastic bushings and plug the
power cord into a 3-prong grounded wall
receptacle near the firebox.
b. If your firebox installation is recessed
and/or pre-wired, see Built-In Installation
of Blower Accessory
, column 2.
8. Turn on power to duplex outlet if previously
turned off per the warning in step 1.
9.
Check to make sure that the power cord is com-
pletely clear of the blower wheel and that there
are no other foreign objects in blower wheel.
Turn blower on and check for operation.
WARNING: Never touch the
blower wheel while in operation.
10. Peel off the backing paper and stick the sup-
plied wiring diagram decal on the firebox
bottom approximately 12" in front of the
blower.
11. Replace bottom of firebox.
Note: Make sure
the back of the firebox bottom slides under
the rear of the firebrick (lift the firebrick up if
necessary.)
12. Reattach firebox bottom using 4 screws re
-
moved in step 1. Note: Discard the remaining
hardware items.
13. Install the log set heater according to the instal
-
lation instructions supplied with the heater.
INSTALLATION
Continued
NOTICE: A qualified electrician
must connect electrical wiring to
duplex outlet for built-in instal-
lation. Follow all local codes. In
absence of local codes follow
The National Electrical Code
ANSI/NFPA 70.
Built-In Installation of Blower Accessory
1. Before replacing bottom of firebox, remove
screw holding duplex outlet to the support
bracket in the bottom of firebox. Remove
duplex outlet.
2. Clamp electrical cable into firebox through
smallest hole in outer casing using strain relief
provided.
3. Route wires from electrical box through hole
in side of heater and hole in support bracket
(see Figure 12).
4. Connect wires from the electrical box to
duplex outlet. Match wire colors to those
indicated on duplex outlet. Be sure to connect
ground wire.
5. Replace duplex outlet with screw.
6. Plug blower power cord into duplex outlet.
7. Replace bottom of firebox.
Figure 11 - Installing Plastic Bushing for
Power Cord
Plastic
Bushing
Figure 12 - Routing Blower Accessory
Power Cord for Built-In Installation
Screw
Blower
Power Cord
Support Bracket
Cables From
Electrical Source
Duplex
Outlet
Blower
Operating the Blower
Light your gas appliance with the blower off. After
about 15 minutes, turn the blower on to deliver
heated air at the top louvers. The blower features
a variable control which allows you to select the
speed you desire.
Note: Periodically check the louvers of the firebox
and remove any dust, dirt or other obstructions.