Vanguard Heating SCIVFB, SCIVFG, SCIVFC, SCIVFR Stove User Manual


 
IMPORTANT: Refer to the Owners Operation and Installation Manual included
with your SVYD18P and SVYD18N Amity
Vent-Free Gas Log Heater for all
assembly and installation instructions and contents listing.
SAFETY
INFORMATION
WARNINGS
Continued
WARNING: Any change to this stove or its controls can be dangerous.
1. This stove shall not be installed in a bedroom or bathroom.
2. Never install the stove
in a recreational vehicle
where curtains, furniture, clothing, or other flammable objects are less
than 36 inches from the front, top or sides of the stove
in high traffic areas
in windy or drafty areas
3. Do not use this stove as a wood-burning fireplace. Use only SVYD18P or
SVYD18N Vent-Free Gas Log Heaters.
4. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock
wool. Using these added items can cause sooting.
5. Do not allow fans to blow directly into the stove. Avoid any drafts that alter
burner flame patterns. Altered burner patterns can cause sooting.
6. Do not use a blower insert or heat exchanger insert with this stove.
7. Vent-free gas log heaters installed in these stoves require fresh air ventila-
tion to run properly. See Air for Combustion and Ventilation in the SVYD18
Owner’s Operation and Installation manual.
8. Do not run stove
where flammable liquids or vapors are used or stored
under dusty conditions
9. Do not use this stove to cook food or burn paper or other objects.
10. Never place any objects in the stove or on logs.
11. Stove sides, front and top become very hot when running stove. Keep chil-
dren, adults and pets away from hot surfaces to avoid burns or clothing igni-
tion. Stove will remain hot for a time after shut-down. Allow surfaces to
cool before touching.
12. Carefully supervise young children when they are in the room with stove.
13. Turn stove off and let cool before servicing. Only a qualified service person
should service and repair stove.
14. Operating stove above elevations of 4,500 feet could cause pilot outage.
!
INTERNATIONAL
2701 Industrial Drive 103973-01
P.O. Box 90004 Rev. A
Bowling Green, KY 42102-9004 4/97