www.desatech.com
113111-01H 19
INSTALLATION
Continued
CONNECTIONS
1. Open equipment shutoff valve (see Figure
25, page 18).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of replace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to thermostat gas valve (see Fig-
ures 26 and 27). Apply a noncorrosive
leak detection uid to gas joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light replace (see Operation). Check all
other internal joints for leaks.
7. Turn off replace (see To Turn Off Gas to
Appliance, page 21).
8. Replace front panel.
Figure 26 - Checking Gas Joints for
Propane/LP Gas (Shown with Optional
Mantel)
Equipment
Shutoff Valve
Propane/LP
Supply Tank
Figure 27 - Checking Gas Joints for
Natural Gas (Shown with Optional Mantel)
Equipment
Shutoff Valve
Gas Meter
OPERATION
FOR YOUR SAFETY
WARNING: If you do not fol-
low these instructions exactly,
-
WHAT TO DO IF YOU SMELL GAS
-