1. Operate SILENCE button;
2. Call your emergency services, fire department or 911. Write down the number of your local
emergency service here:
3. Immediately move to fresh air - outdoors or by an open door/window. Do a head count to check
that all persons are accounted for. Do not reenter the premises nor move away from the open
door/window until the emergency services responders have arrived, the premises have been
aired out and your alarm remains in its normal condition.
4. After following steps 1-3, if your alarm reactivates within a 24 hour period, repeat steps 1-3
and call a qualified appliance technician to investigate for sources of CO from fuel-burning
equipment and appliances and inspect for proper operation of this equipment. If problems
are identified during this inspection, have the equipment serviced immediately. Note any
combustion equipment not inspected by the technician and consult the manufacturers'
instructions or contact the manufacturer(s) directly for more information about CO safety and
this equipment. Make sure that motor vehicles are not, and have not been, operating in an
attached garage or adjacent to the residence. Write down the number of your local emergency
service here:
Page 7
IF THE CO ALARM SOUNDS:
WHAT TO DO IF NATURAL GAS IS DETECTED:
1. Leave the house immediately, opening doors and windows as you leave.
2. Do not use your telephone or appliances. Do not turn any light switches off or on. Any
spark or flame could ignite the gas.
3. Call 911 and your gas company from a phone that is away from your home.
4. Do not reenter the area until the source of the leak is found and corrected.
If you hear the alarm horn sound 1 beep per second, gas has
been detected. Evacuate everyone from the building.
If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous
situation which requires your immediate attention. NEVER ignore any alarm. Ignoring the
alarm may result in injury or death.
USING THE SILENCE FEATURE
NEVER disconnect the power to your alarm to silence the horn - use the Silence feature. Disconnecting
the alarm removes your protection!
• The Silence feature is intended to temporarily silence the horn while you identify and
correct the problem.
• To use the Silence feature, press and release the SILENCE button until the horn is
silent.
• If the SILENCE button is pressed while the alarm is in the silence mode, the alarm will
start sounding again.
WHEN THE CO ALARM SIGNAL IS SILENCED: The CO alarm will remain silent for up to 4 minutes
(with the red LED blinking on approx. every 10 seconds, until reset) and then return to normal
operation. It will continue to monitor the air for CO. Ventilate area. After up to 4 minutes, depending
on the level of CO detected, if CO levels remain potentially dangerous, the horn will start sounding
again.
WHEN THE GAS ALARM SIGNAL IS SILENCED: The alarm will remain silent for approximately
20 seconds (with the blue LED blinking on approx. every 10 seconds, until reset) and then return to
normal operation. Ventilate area. If the gas has not cleared within the silence period, the unit will go
back into alarm.
IMPORTANT!
The Silence feature is intended to temporarily silence the alarm horn. It will not correct a CO or Gas
problem.