Turbo Air MSR-23G-1 Door User Manual


 
ELECTRONIC CONTROL INSTRUCTION
21
No
2
1
Temperature
Control
Initial
Operation
Compressor
LED
1. 88 LED displays inside temperture
2. Begin to run immediately on the higher than 41 and
begin to run after 5 minutes pause on the lower
than 41 .
1. The temperature can be changed by pushing up/down
buttons.
2. 88 LED displays inside temperture
3. Buzzer buzzes 1time whenever a button is pressed
4. Compressor automatically turns on and off by C-sensor
(Except errer mode)
5. Comp. on/off temperature ( )
Setting 39 38 37 36 35
Comp On 39.0 39.0 39.0 39.0 39.0
Comp OFF 30.2 28.4 27.5 27.0 25.0
-----------------------------------------------------------------
Setting 34 32 30 28
Comp On 39.0 39.0 39.0 39.0
Comp OFF 23.0 21.2 19.0 17.6
Function
Controlled
Part
Description
ERROR CODE
Code
T-sensor
S
O
S
O
- Normal operation
- Time control
Comp ON : 10 MINUTES
Comp OFF : 20 MINUTES
- short circuit
- wire disconnection
- short circuit
- wire disconnection
- short circuit
- wire disconnection
C-sensor
C-sensor
T-sensor
Content Perception Method Refrigeration state
5-2-2. FUNCTION TABLE
ELECTRONIC CONTROL INSTRUCTION
20
5-2. REFRIGERATOR CONTROL
5-2-1. HOW TO USE THE DISPLAY PCB PANEL
- 88 LED
- It indicates setting temperature,
except defrost function
-Door Open LED
-Temperature can be controlled by the user.
-Factory setting is at level "35 ". Setting can
be changed by pressing up/down button.
SENSOR DESCRIPTION
Sensor
D-sensor
Freezer
Detect Eva coil’s temp. to terminate
defrosting
WHT
BLK
BLK
WHT
C-sensor
T-sensor
Freezer
Refrigerator
Refrigerator
Detect inside air temp. to operate comp and to
indicate the inside temp. on the display PCB
Detect Eva coil’s temp. to operate comp
Detect inside air temp. to indicate the inside temp
on the display PCB
Model Role Wire Color