How It Works
A high-voltage ionizer within the air cleaner electrically
charges airborne pollutants and particles. Trion
®
electronic air cleaners feature electrostatic precipitators
– a series of metal collection plates that are oppositely
charged to the ionized particles. The negative lter plate
then attracts and captures these microscopic particles,
preventing them from being recirculated into the home.
Trion
®
systems offer high performance and efciency,
ultra-quiet operation and no lters to replace.
Installation Methods
Trion
®
electronic air cleaners work within
all types of heating and cooling system
congurations. Trion
®
whole-house air
cleaners can be easily installed and are
suitable for use with all types of central
forced-air heating and cooling system
congurations. These illustrations show
you where the air cleaners should be
installed in four common setups.
Clean and Re-use
Our exclusive Forever Filter
®
attracts and captures charged
dust and dirt particles on aluminum plates that are simply lifted
out and rinsed off in the sink. Not only is this responsible to the
environment but there are no expensive lters to replace!
R
Downow
Upow
Horizontal
HE Series Electronic Air Cleaners
Trion
®
electronic air cleaners easily attach directly to your home’s heating
and cooling system ductwork, passing recirculated air through the air cleaner.
A permanent, washable, aluminum mesh pre-lter captures large particles
in the air pulled in by the furnace blower. High-voltage ionization within the
Trion
®
exclusive Forever Filter
®
purifying cell then attracts and captures
the particles on alternately charged aluminum plates, ltering up to 95% of
particles as minute as 0.1 micron and preventing harmful irritants from being
constantly recirculated.
The permanent, aluminum air purifying cells can be easily removed for cleaning, so there are no replacement
lters to buy – ever. An optional, replaceable charcoal after-lter greatly reduces common household odors.
Available in three sizes and capable of cleaning 1,400 to 2,000 cubic feet per minute (CFM), Trion
®
air
cleaners feature a standard, built-in airow sensor so that the air cleaner is only running when the heating or
air conditioning equipment is running to reduce energy consumption.
HE Plus 2000HE Plus 1400
Pre-lter Collection
Plates
Optional
Charcoal Filter
Dirty Air
Clean Air
Ionizer
Pre-Filter Ionizer Collection
Plates
Optional
Charcoal Filter