Trion 707-U Humidifier User Manual


 
www.trioninc.com
707-U
Atomizing Humidifier
©2008 Trion
®
-IndoorAirQualitySolutions|Herrmidier
®
-EngineeredHumidicationSolutionsTrion
®
andHerrmidier
®
are registered trademarks
ofAirSystemComponents,Inc.Trion
®
reservestherighttoreviseormodifyproductsand/orspecicationswithoutnotice.
Allproductspecicationsreectavailableinformationattheprintingofthisbrochure.
Trion
®
|101McNeillRoad|Sanford,NC27330|Phone:800-884-0002|Fax:800-458-2379
Web: www.trioninc.com | Email: customerservice@trioninc.com
H-707U-1008
TECHNICAL ENGINEERING SPECIFICATION
Air Purification Systems
Evaporator Supply Capacity
Humidifier Capacity Selection Guide
Furnace Temp. 707-U
°F °C Gallons per Day Liters per Hour
100°F 37.7°C 6.0 0.95
120°F 48.8°C 6.0 0.95
140°F 60°C 6.0 0.95
Model 707-U
Part No. 356686-001
Type Of Unit Centrifugal Atomizer
Max Evaporative Capacity 6.0GallonsPerDay-(0.95Lph)
Voltage 120 V
Unit Weight 11Lbs(5.0Kg)
Shipping Weight 13Lbs(5.9Kg)
Dimensions
10 1/2" Diameter x 12" H / Packaging - 13 1/4" W x 13 1/4" D x 16 3/4" H
(276mmx305mm)/(Packaging-336Wx336DX425Hmm)
Water Supply 1/4"(6.4mm)CopperorPlastic,125PSI(8.6Bar),NotIncluded
Drain 1/2"(13mm)
Humidistat Adjustable from 20% to 80% Relative Humidity
Drain 1/2”(12.8mm)O.D.
707-U
Sq. Footage (m) of Home Tight
1
House Average
2
House Loose
3
House
1000 (92.9m
2
) 0.5 (0.08) 5.0 (0.8) 10.0 (1.6)
1500 (139.4m
2
) 3.0 (0.5) 10.0 (1.6) 16.5 (2.6)
2000 (185.8m
2
) 5.0 (0.8) 14.0 (2.2) 24.0 (3.8)
2500 (232.3 m
2
) 7.5 (1.2) 19.0 (3.0) 30.5 (4.8)
3000 (278.7 m
2
) 10.0 (1.6) 23.5 (3.7) 37.5 (5.9)
3500 (325.2m
2
) 14.5 (2.3) 33.0 (5.2) 51.5 (8.1)
1.A“TightHome”isassumedtobewellinsulatedwithvaporbarriers,tightstormwindowsanddoors,andadamperedreplace.Airexchangerateof.5changesperhour.
2.An“AverageHome”isinsulatedandhasadamperedreplace,buttherearenovaporbarriers,stormdoors,orstormwindows.Airexchangerateof1.0changeperhour.
3.A“LooseHome”isgenerallyoneconstructedbefore1930,haslittleornoinsulation,nostormdoors,stormwindows,weatherstrippingorvaporbarriers,andoftenno
effectivedamperingofreplaces.Airexchangerateisashighas1.5changesperhour.
Cold Air Return Duct
Discharge
Dome
Wire Mounting
Bracket
Extension
Nozzle
Discharge
Extension
Nozzle
Outside
Wall
Inside Wall
Installation Options