33
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
GAS CONVERSION KITS
IMPORTANT
CANADA ONLY
The conversion shall be carried
out in accordance with the require-
ments of the provincial authorities
having jurisdiction and in accor-
dance with the requirements of
the CAN1-B149.1 And B149.2
Installation code.
Natural Gas to Propane Gas
Conversion Kits
Fireplace
Type
Cat. No.
(model)
Millivolt
85L65
FGCK-DMOMNP
Electronic
85L79
FGCK-DMOENP
Table 12
Propane Gas to Natural Gas
Conversion Kits
Fireplace
Type
Cat. No.
(model)
Millivolt
85L72
FGCK-DMOMPN
Electronic
85L86
FGCK-DMOEPN
Table 13
Gas conversion kits are available to adapt the
appliance from the use of one type of gas to
the use of another. These kits contain all the
necessary components needed to complete the
task including labeling that must be affi xed to
ensure safe operation.
Kit part numbers are listed here and the following
steps detail the conversion procedure.
Step 1. Turn off the gas supply to the appliance.
Remove the front glass door/frame from the ap-
pliance (see Removing Glass Enclosure Panels
on Page 29). Remove the control compartment
door (see Control Compartment Door Removal
on Page 27).
Step 2. Carefully remove the logs. Exercise
care so as not to break the logs.
Step 3. Referring to Figure 58, remove the
front burner and then the rear burner.
WARNING
This conversion kit shall be
installed by a qualifi ed service
agency in accordance with the
manufacturer's instructions and
all applicable codes and require-
ments of the authorized having
jurisdiction. If the information in
these instructions is not followed
exactly, a fi re, explosion or pro-
duction of carbon monoxide may
result causing property damage,
personal injury or loss of life.
The installation is not proper and
complete until the operation of the
converted appliance is checked as
specifi ed in the owner instructions
supplied with the kit. The qualifi ed
service agency performing this
installation assumes responsibil-
ity for this conversion.
FRONT OF FIREPLACE
REAR BURNER
FRONT BURNER
VENTURI
TUBE ARM
VENTURI
TUBE ARM
AIR SHUTTER
ADJUSTMENT LEVER
FIREBOX SUBFLOOR
NOTE: REMOVE FRONT BURNER FIRST,
THEN REAR BURNER.
Figure 58
Step 4. Millivolt Appliances - SIT Systems
a. See Figure 59 and the instructions
provided with the kit. Using a Torx T20,
tool or or standard fl at screwdriverremove
and discard the three pressure regulator
mounting screws. Remove the pressure
regulator, spring, poppet, diaphragm and
bushing. Discard all removed components.
Ensure the rubber gasket installed on the
back of the replacement pressure regulator
is properly positioned and install the new
pressure regulator using the new screws
supplied with the kit. Tighten screws to 25
In. lb. torque.
AVERTISSEMENT
Cet Équipement de conversion
sera installÉ par une agence
qualifi Ée de service conformÉ-
ment aux instructions du fabri-
cant et toutes exigences et codes
applicables de l’autorisÉs avoir
la juridiction. Si l’information
dans cette Instruction n’est pas
suivie exactement, un feu, explo-
sion ou production de protoxyde
de carbone peut rÉsulter le
dommages causer de propriÉtÉ,
perte ou blessure personnelle
de vie. L’agence qualifiÉe
de service est esponsable de
l’installation propre de cet
Équipment. L’installation n’est
pas propre et complÉte jusqu’à
l’opÉration de l’appareil converti
est chÉque suivant les critères
Établis dans les instructions de
propriÉtaire provisionnÉes avec
l’Équipement.
ATTENTION
LE CANADA SEULEMENT
La conversion devra être effec-
tuée conformément aux recom-
mandations des autorités pro-
vinciales ayant juridiction et
conformément aux exigences du
code d'installation CAN1-B149.1
Et.2.