Trane TUH2C100A9V5VA Furnace User Manual


 
18
Pub. No. 22-1814-08
*DH2C100A9V4V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY =
2nd STAGE CAPACITY =
62,400
96,000
AIRFLOW
SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING
1ST
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
923
61
110
955
59
165
960
58
210
958
58
265
947
59
310
MEDIUM LOW OFF ON
CFM
TEMP. RISE
WATTS
1020
55
145
1047
53
190
1053
53
250
1042
54
295
1029
54
350
MEDIUM ** ON OFF
CFM
TEMP. RISE
WATTS
1156
48
185
1166
48
240
1172
48
300
1177
48
350
1178
48
420
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1275
44
225
1305
43
290
1328
42
365
1328
42
445
1328
42
510
HEATING
2ND
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
1298
66
235
1320
65
305
1335
65
380
1343
64
445
1343
64
520
MEDIUM LOW OFF ON
CFM
TEMP. RISE
WATTS
1439
60
310
1459
59
390
1482
58
470
1483
58
550
1470
59
610
MEDIUM ** ON OFF
CFM
TEMP. RISE
WATTS
1639
53
430
1650
52
525
1650
52
600
1644
52
680
1496
58
640
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1790
18
570
1818
47
670
1813
47
770
1708
50
750
1535
56
675
NOTES: * - First letter may be "A" or "T"
** Factory setting
*** Above MAX temperature change
*DH2C100A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.5
LOW
(350 CFM/TON)
ON ON OFF ON
CFM
WATTS
870
100
885
140
887
185
881
230
876
270
NORMAL
(400 CFM/TON)
ON ON OFF OFF
CFM
WATTS
989
120
1018
180
1016
230
1012
285
999
325
HIGH
(450 CFM/TON)
ON ON ON OFF
CFM
WATTS
1124
175
1139
225
1130
275
1135
335
1135
390
3.0
LOW
(350 CFM/TON)
OFF ON OFF ON
CFM
WATTS
1053
145
1075
200
1070
245
1070
295
1049
350
NORMAL
(400 CFM/TON)
OFF ON OFF OFF
CFM
WATTS
1186
195
1205
255
1220
310
1220
370
1216
440
HIGH
(450 CFM/TON)
OFF ON ON OFF
CFM
WATTS
1336
255
1366
340
1383
405
1385
470
1381
545
3.5
LOW
(350 CFM/TON)
ON OFF OFF ON
CFM
WATTS
1216
190
1225
255
1235
320
1240
385
1243
445
NORMAL
(400 CFM/TON)
ON OFF OFF OFF
CFM
WATTS
1394
270
1422
360
1436
430
1437
505
1430
580
HIGH
(450 CFM/TON)
ON OFF ON OFF
CFM
WATTS
1579
395
1604
475
1610
555
1599
645
1517
640
4.0
LOW
(350 CFM/TON)
OFF OFF OFF ON
CFM
WATTS
1377
270
1412
355
1426
430
1433
510
1428
575
NORMAL
(400 CFM/TON)
OFF OFF OFF OFF
CFM
WATTS
1599
425
1624
510
1636
585
1618
670
1512
635
HIGH
(450 CFM/TON)
OFF OFF ON OFF
CFM
WATTS
1801
580
1818
690
1815
775
1694
735
1525
660
NOTES: * - First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airow (400 cfm/ton) is typical setting;
HIGH airow (450 cfm/ton) is DRY CLIMATE setting.