Trane TUH2B080A9V3VA Furnace User Manual


 
2
Pub. No. 22-1814-08
General
Features
© 2012 Trane All Rights Reserved
NATURAL GAS MODELS
Central Heating furnace designs are
certified by the American Gas Associa-
tion for both natural and L.P. gas. Limit
setting and rating data were established
and approved under standard rating
conditions using American National
Standards Institute standards.
SAFE OPERATION
The Integrated System Control has
solid state devices, which continuously
monitor for presence of flame, when
the system is in the heating mode of
operation. Dual solenoid combination
gas valve and regulator provide addi-
tional safety.
QUICK HEATING
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm
conditioned air to the structure. Low
energy power vent blower, to in-
crease efficiency and provide a positive
discharge of gas fumes to the outside.
BURNERS
Multiport Inshot burners will give years
of quiet and efficient service. All models
can be converted to L.P. gas without
changing burners.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational pro-
gram provides total control of furnace
limit sensors, blowers, gas valve, flame
control and includes self diagnostics
for ease of service. Also contains con-
nection points for E.A.C./Humidifier.
AIR DELIVERY
The variable speed blower motor has
sufficient airflow for most heating and
cooling requirements and will switch
from heating to cooling speeds on
demand from room thermostat. The
blower door safety switch will prevent
or terminate furnace operation when
the blower door is removed.
SECONDARY HEAT EXCHANGER
The XV95 has a special type 29-
4C stainless steel secondary heat
exchanger to reclaim heat from flue
gases which would normally be lost
instead.
STYLING
Heavy gauge steel and “wrap-
around” cabinet construction is
used in the cabinet with baked-on
enamel finish for strength and beauty.
The heat exchanger section of the
cabinet is completely lined with foil
faced fiberglass insulation. This results
in quiet and efficient operation due to
the excellent acoustical and insulating
qualities of fiberglass. Built-in bottom
pan and alternate bottom, left or right
side return air connection provision.
FEATURES AND GENERAL
OPERATION
The XV95 High Efficiency Gas Fur-
naces utilize an Adaptive Heat Up
Silicon Nitride Hot Surface Ignition
system, which eliminates the waste of
a constant burning pilot. The integrated
system control lights the main burners
upon a demand for heat from the room
thermostat. Complete front service ac-
cess.
a. Low energy power venter
b. Vent proving pressure switch.