Note : Data includes pressure drops for standard filters and wet coils
Table 30 - WSD 060 Available static pressure
External Static Pressure (Pa)
25 50 75 100 125 150 175 200 225 250 275 300
m
3
/h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW kW kW
2720 - - - - - - ------9330.479750.5310140.5810500.6310850.6811180.72
3060 - - - - - - - - 892 0.48 935 0.52 976 0.57 1016 0.62 1056 0.68 1093 0.74 1128 0.80 1160 0.86
3400 - - - - - - 904 0.55 945 0.60 985 0.65 1023 0.70 1061 0.75 1098 0.80 1135 0.86 1170 0.93 1203 1.00
3740 - - - - 913 0.63 959 0.68 1001 0.74 1038 0.80 1074 0.85 1109 0.90 1143 0.96 1177 1.01 1212 1.07 1244 1.14
4080 - - 933 0.74 972 0.78 1014 0.84 1056 0.90 1094 0.97 1128 1.03 1160 1.09 1193 1.15 1225 1.20 1256 1.26 1287 1.32
325 350 375
m
3
/h kW kW kW
2720 1151 0.78 1183 0.83 1214 0.88
3060 1192 0.91 1223 0.97 1252 1.02
3400 1235 1.06 1265 1.12 1295 1.19
3740 1276 1.21 1308 1.29 - -
4080 - - - - - -
Fan
RPM
Fan
RPM
Fan
RPM
Fan
RPM
Fan
RPM
Table 31 - WSH 060 Available static pressure
External Static Pressure (Pa)
25 50 75 100 125 150 175 200 225 250 275 300
m
3
/h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW kW kW
2720 - - - - - - - - 941 0.47 990 0.52 1034 0.58 1077 0.64 1119 0.70 1158 0.75 1196 0.82 1231 0.88
3060 - - - - - - 937 0.52 992 0.58 1043 0.65 1088 0.71 1130 0.77 1169 0.83 1207 0.90 1244 0.96 1280 1.03
3400 - - - - 945 0.58 995 0.65 1045 0.72 1094 0.79 1141 0.86 1185 0.93 1224 1.00 1260 1.07 1295 1.14 1330 1.21
3740 901 0.60 958 0.67 1009 0.73 1057 0.80 1101 0.88 1146 0.95 1192 1.03 1235 1.11 1277 1.18 1314 1.26 - - - -
4080 973 0.76 1026 0.84 1075 0.91 1120 0.98 1163 1.06 1204 1.14 1245 1.23 - - - - - - - - - -
325 350 375
m
3
/h kW kW kW
2720 1265 0.94 1298 1.00 1330 1.07
3060 1314 1.10 1346 1.16 1380 1.24
3400 1363 1.28 - - - -
3740 - - - - - -
4080 - - - - - -
Fan
RPM
Fan
RPM
Fan
RPM
Fan
RPM
Fan