Trane TAM7A0B30H21SB Air Conditioner User Manual


 
22 Pub. No. 22-1847-03
Two Stage Cooling
Field
Wiring
Comfort Control
Air Handler
Air Conditioner
Neatly bundle all low voltage
wires behind the service
valve cover as shown.
Yellow/Red
Field wiring
Yellow/Black
Blue
Red
Yellow
Green
White
Blue
B
B - Blue
W
G
Y1
Brown
Y2
Y1 - Yellow
Y2 - Brown
R
O
O
R
B
YI
W1
YO
Y2
BK
G
W2
W3 *
(In)
(Out)
* For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat.
YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly.
Internally mounted condensate switch is optional and must be ordered separately.
If 3rd party condensate overflow switches are installed, they should be wired in series between YO and Y to the outdoor unit.