Trane GAF2A0A24S21SA Air Conditioner User Manual


 
8 Pub. No. 22-1858-02
Performance
Data
GAF2A0A24 AIRFLOW PERFORMANCE TABLE
AIRFLOW PERFORMANCE
GAF2A0A24S21SA
EXTERNAL STATIC
(in w.g)
AIRFLOW (CFM)
Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS
3 2 † 1 3 2 † 1
0 998 848 771 899 737 658
0.1 949 816 745 868 710 630
0.2 911 784 711 834 683 602
0.3 869 750 679 794 650 567
0.4 825 708 638 756 611 524
0.5 772 659 586 704 547 476
0.6 707 591 518 641 499 415
0.7 614 513 444 555 420 346
0.8 533 416 356 465 339 268
0.9 413 309 218 351 203 138
1.0 241 130 N/A 167 N/A N/A
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. † Factory Setting
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #2.
GAF2A0A24S21SA MINIMUM HEATER AIRFLOW CFM
Heater Minimum Air Speed Tap
Without Heat Pump With Heat Pump
BAYECAA05LG1AA Tap 1 Tap 2
BAYECAA08LG1AA Available soon Available soon
BAYECAA10LG1AA Available soon Available soon
SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS