Trane 4TWB4 Heat Pump User Manual


 
22-1834-09 5
General
Data
Product Specifications
Model No. 1 4TWB4042E1 4TWB4048E1 4TWB4049E1 4TWB4060E1 4TWB4061E1
Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60
Min Cir Ampacity 27 29 28 35 36
Max Fuse Size (Amps) 45 50 50 60 60
Compressors
CLIMATUFF
® -
SCROLL CLIMATUFF
® -
SCROLL CLIMATUFF
® -
SCROL CLIMATUFF
® -
SCROLL CLIMATUFF
® -
SCROL
RL AMPS - LR AMPS 19.9 - 109 21.8 - 117 21.8 - 117 26.4 - 134 26.4 - 134
Outdoor Fan FL Amps 0.93 0.93 1.00 0.93 2.80
Fan HP 1/5 1/5 1/5 1/5 1/3
Fan Dia (inches) 27.6 27.6 27.6 27.6 27.6
Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™
Refrigerant R-410A 12/1-LB/OZ 13/9-LB/OZ 13/10-LB/OZ 12/1-LB/OZ 13/12-LB/OZ
Line Size - (in.) O.D. Gas 3 3/4 7/8 7/8 7/8 1-1/8
Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 3/8
Dimensions H x W x D (Crated)
46.4 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7
51 x 35.1 x 38.7
Weight - Shipping 313 331 331 332 332
Weight - Net 277 294 294 295 295
Start Components NO NO NO YES YES
Sound Enclosure NO NO NO NO NO
Compressor Sump Heat YES YES YES YES YES
Optional Accessories: 4
Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A
Evaporator Defrost Control A/C AY28X084 AY28X084 AY28X084 AY28X084 AY28X084
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101
Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260
Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004
Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002
Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003
Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001
Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3* TAYREFLN3* TAYREFLN3* TAYREFLN3*
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0
. (
denotes latest revision)
4 For accessory description and usage, see page 5.
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.