22-1817-10 5
General
Data
Product Specifications
Model No. 1 4TTX5042A1 4TTX5048A1 4TTX5049E1 4TTX5060A1 4TTX5061E
Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 230/1/60
Min Cir Ampacity 26 28 28 34 39
Max Fuse Size (Amps) 45 50 45 60 60
Compressor
CLIMATUFF
®
- SCROLL CLIMATUFF
®
- SCROLL CLIMATUFF
®
- SCROLL CLIMATUFF
®
- SCROLL CLIMATUFF
®
- SCROLL
No. Used - No. Stages 1-1 1-1 1-1 1-1 1-2
RL Amps - LR Amps 19.9 - 109 21.8 - 117 19.9 - 109 26.4 - 134 28.8 - 152.9
Outdoor Fan FL Amps 0.93 0.93 2.8 0.93 2.8
Fan HP 1/5 1/5 1/3 1/5 1/3
Fan Dia (inches) 27.6 27.6 27.6 27.6 27.6
Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™
Refrigerant R-410A 7/00-LB/OZ 11/00-LB/OZ 11/9-LB/OZ 11/00-LB/OZ 12/9-LB/OZ
Line Size - (in.) O.D. Gas 3 3/4 7/8 7/8 1-1/8 1-1/8
Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 3/8
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7
Weight - Shipping 305 352 324 354 332
Weight - Net 257 302 287 304 295
Start Components NO NO NO YES NO
Sound Enclosure YES YES NO YES NO
Compressor Sump Heat NO NO NO NO NO
Optional Accessories: 4
Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A
Evaporator Defrost Control A/C AY28X079 AY28X079 AY28X079 AY28X079 AY28X079
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101
Crank Case Heater Scroll BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301
Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260
Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT004 BAYECMT001 BAYECMT004
Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002
Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003
Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001
Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3* TAYREFLN3* TAYREFLN4* TAYREFLN*4
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For 061 units, Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0
†
. (
†
denotes latest revision)
4 For accessory description and usage, see page 5.
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.