Trane 080 Furnace User Manual


 
9Pub. No. 22-1682-05-0802 (EN)
Performance
Data
TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
(See Notes)
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.0
LOW
(350 CFM/TON)
ON ON OFF ON
CFM
WATTS
1040
165
1040
220
1040
270
1030
320
1030
375
NORMAL
(400 CFM/TON)
ON ON OFF OFF
CFM
WATTS
1210
235
1210
285
1230
360
1230
415
1230
475
HIGH
(450 CFM/TON)
ON ON ON OFF
CFM
WATTS
1340
390
1370
390
1400
465
1390
525
1370
580
3.5
LOW
(350 CFM/TON)
OFF ON OFF ON
CFM
WATTS
1200
225
1220
280
1230
365
1250
425
1230
485
NORMAL
(400 CFM/TON)
OFF ON OFF OFF
CFM
WATTS
1390
335
1430
425
1430
495
1430
560
1400
590
HIGH
(450 CFM/TON)
OFF ON ON OFF
CFM
WATTS
1590
490
1590
575
1590
625
1580
685
1420
615
4.0
LOW
(350 CFM/TON)
ON OFF OFF ON
CFM
WATTS
1370
325
1420
415
1430
490
1340
550
1410
595
NORMAL
(400 CFM/TON)
ON OFF OFF OFF
CFM
WATTS
1640
515
1640
585
1640
655
1590
680
1420
615
HIGH
(450 CFM/TON)
ON OFF ON OFF
CFM
WATTS
1840
700
1840
780
1770
795
1630
725
1470
655
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY100R9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =
2nd Stage Capacity =
62,000
93,000
AIRFLOW
SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING
1ST
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
920
60
130
920
60
180
920
60
220
920
60
280
920
60
320
MEDIUM LOW OFF ON
CFM
TEMP. RISE
WATTS
1020
54
165
1020
54
220
1020
54
260
1010
55
310
1000
56
365
NORMAL ** ON OFF
CFM
TEMP. RISE
WATTS
1160
48
220
1160
48
260
1160
48
325
1160
48
390
1150
48
430
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1350
41
320
1380
40
400
1400
40
470
1400
40
540
1390
40
585
HEATING
2ND
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
1290
67
275
1290
67
355
1330
65
430
1340
64
490
1320
65
545
MEDIUM LOW OFF ON
CFM
TEMP. RISE
WATTS
1410
61
3561
1460
59
455
1460
59
520
1460
59
590
1370
63
590
NORMAL ** ON OFF
CFM
TEMP. RISE
WATTS
1640
53
530
1640
53
590
1640
53
660
1600
54
695
1410
61
620
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1970
44
855
1920
45
895
1780
48
820
1660
52
760
1520
57
695
NOTES:
** Factory setting