Toshiba XXXXXXX(X/X)
–17–
4-way Air Discharge Cassette Type
Owner’s Manual
11.ADVANCED SETTINGS
Swing mode
1 Push for at least four seconds when
the air conditioner is not working.
• , symbol, and numbers flash.
2 Push (left side of the button) to select
an indoor unit to be set.
• Each time you push the button, the unit numbers
change as follows:
The fan of the selected unit runs and the louvers
start swinging.
3 Push TIME buttons to select a swing
type.
Three types of swings are available:
• Standard swing
The four louvers swing in the same direction.
• Dual swing
Louvers 01 and 03 are directed and swing in
one direction, and/then louvers 02 and 04 are
directed and swing in the opposite direction.
(When louver 01 is directed downward, louver
02 is directed horizontally.)
• Cycle swing
The four louvers swing independently at
respective timings.
CAUTION
• Do not set the SET DATA to “0000”.
(This setting may cause a failure of the louvers.)
4 Push button.
5 Push button to complete the setting.
1
2
3
Not
display
UNIT No.
1-1
UNIT No.
1-2
UNIT No.
1-3
UNIT No.
1-4
SET DATA Swing of louvers
0001
Standard swing
(Factory default)
0002 Dual swing
0003 Cycle swing
04 02
03
01
Refrigerant
pipe
Drain
pipe
SET DATA
17-EN
+00EH99933501_00Ta.book Page 17 Tuesday, November 24, 2009 2:25 PM