Toshiba RAV-SP240UT-UL Air Conditioner User Manual


 
Toshiba XXXXXXX(X/X)
–17–
4-way Air Discharge Cassette Type
Owner’s Manual
11.ADVANCED SETTINGS
Swing mode
1 Push for at least four seconds when
the air conditioner is not working.
, symbol, and numbers flash.
2 Push (left side of the button) to select
an indoor unit to be set.
Each time you push the button, the unit numbers
change as follows:
The fan of the selected unit runs and the louvers
start swinging.
3 Push TIME buttons to select a swing
type.
Three types of swings are available:
Standard swing
The four louvers swing in the same direction.
Dual swing
Louvers 01 and 03 are directed and swing in
one direction, and/then louvers 02 and 04 are
directed and swing in the opposite direction.
(When louver 01 is directed downward, louver
02 is directed horizontally.)
Cycle swing
The four louvers swing independently at
respective timings.
CAUTION
Do not set the SET DATA to “0000”.
(This setting may cause a failure of the louvers.)
4 Push button.
5 Push button to complete the setting.
1
2
3
Not
display
UNIT No.
1-1
UNIT No.
1-2
UNIT No.
1-3
UNIT No.
1-4
SET DATA Swing of louvers
0001
Standard swing
(Factory default)
0002 Dual swing
0003 Cycle swing
04 02
03
01
Refrigerant
pipe
Drain
pipe
SET DATA
17-EN
+00EH99933501_00Ta.book Page 17 Tuesday, November 24, 2009 2:25 PM