Toshiba RAS-B10GKVP-E Air Conditioner User Manual


 
47
10. INSTALLATION PROCEDURE
10-1. Safety Cautions
1 Installation plate
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
installation work.
Make sure the drain hose is
sloped downward.
The auxiliary piping can be
connected at the left, rear left,
rear right, right, bottom right or
bottom left as shown below.
Extension drain hose
(Option: RB-821SW)
6 mm thick heat resisting
polyethylene foam
For the rear left and left piping
Do not allow the drain hose
to become slack.
Cut the piping
hole slightly
sloped
Insulate the refrigerant pipes
separately, not together.
250 mm or more
from wall
In principle,
leave open
When installing the outdoor unit,
leave open in at least two of
directions (A), (B), (C) and (D)
shown in the right figure.
Ensure sufficient space
to allow drainage
(A)
(B)
(C)
(D)
Power cord
Y
Wall
Bottom right
Rear
right
Right
Left
Bottom left
Rear left
As shown in the figure, position power cord and
connecting cable downward, and lead out along
piping connection port.
Before installing the wireless remote controller
With the remote controller cover
removed, correctly load the
supplied batteries while
observing their polarity.
3 Batteries
Cover
2 Wireless remote controller
2 Wireless
remote controller
100 mm or more
from wall
4 Remote controller holder
(Mounting holes on both
left and right sides)
8 Remote controller
holder mounting screw
50 mm or more
from wall
80 mm or more only
when unobstructed to
the front and both sides
Air filters
6 Plasma pure filter
5 Zeolite-plus filter
140 mm or more
Hook
Hook
Hook
47 mm or more
74 mm
or more
Z Shield pipe
(for extension
drain hose)
7 Mounting screw
200 mm
or more