Toshiba RAS-18LKH-A Air Conditioner User Manual


 
UNIT OPERATION
EMERGENCY AND TEST OPERATION
Test Operation
This operation is used for checking after unit installation.
Press the TEST button.
Press the TEST button once more after checking to activate remote control. If there is any input
signal ( remote control signal or EMERGENCY button pressed ) during test operation, the TEST mode will
change to the input signal mode.
The setting conditions of the test operation are as follows:
- Operation mode : COOL
- Fan speed : HIGH
- Timer mode : Disable
- Discharge air direction : SWING
Emergency Operation
When the remote control is lost, damaged or the battery is discharged, the EMERGENCY button can be used
to run the unit.
Press the EMERGENCY button at the off mode condition.
- The unit operates automatically according to the room temperature by selecting either the cooling or
the heating operation.
If you want to stop the emergency operation, push the EMERGENCY button again or operate the remote control.
The setting conditions of emergency operation are as follows:
- Operation mode : AUTO
- Preset temperature : 25°c
- Fan speed : AUTO
- Timer mode : Disable
- Discharge air direction : Set automatically according to operation mode. ( Refer to p. 20 )
EMERGENCY
TEST
OWNER
,
S MANUAL - 21