Toshiba RAM-SM800UT-E Air Conditioner User Manual


 
54
1
Push button.
The operation lamp goes on, and the operation starts.
2
Select an operation mode with the “MODE” button.
One push of the button, in each time the display
changes in the order shown on the right.
In HEAT mode, if the room temperature reaches to the set temperature, the outdoor unit stops and
the air flow becomes LOW and the air volume decreases.
In the defrost mode, the fan stops so that cool air is not discharged and PRE-DEF is displayed.
3
Select air volume with “FAN ” button.
One push of the button, in each time the display
changes in the order shown on the right.
When air volume is “AUTO ”, air volume differs according to the room temperature.
In DRY mode, “AUTO ” is displayed and the air volume is LOW.
In heating operation, if the room temperature is not heated sufficiently with fan mode “LOW ” opera-
tion, select “MED. ” or “HIGH ” operation.
4
Determine the set up temperature by pushing the “TEMP. ” or “TEMP. ” button.
CORRECT USAGE
When you use the air conditioner for the first time or when you change SET DATA value, follow the procedure
below. From the next time, the operation will start as set state by pushing the button.
Preparation
Turn on the main power switch and/or the leakage breaker.
When the power supply is turned on, display section is displayed on the remote controller.
*
After the power supply is turned on, the remote controller does not accept an operation for approx. 1 minute,
but it is not a failure.
REQUIREMENT
While using the air conditioner, operate it only with button without turning off the main
power switch and the leakage breaker.
When starting the operation after stop for a long time, turn on the main power switch for 12 hours or
more before start. (This is required to turn on the compressor case heater for warming in order to
prevent overload on the compressor when activating the outdoor unit.)
AUTO HEAT DRY COOL FAN
LOW MED. HIGH
AUTO
UNIT
1
2
4
3
SET