Toshiba RAM-SM560AT-E Air Conditioner User Manual


 
103
Installation of Remote Controllers
Precautions
1. Low-voltage circuit provision is used for remote
controller communication, and as such, the remote
controller cable is subject to the low-power circuit
provision of internal wiring regulations and therefore
it cannot be brought into direct contact with a high-
voltage AC power line, or housed in the same
conduit tube as a power line.
Flush wall mounting
Feed the 3-core cable (obtained locally) though the
back of the remote controller and then connect to the
ABC terminals.
Attach the remote controller to the wall using two
suitable mounting screws (obtained locally).
Wall surface mounting
Attach the remote controller to the wall using two
suitable mounting screws (obtained locally).
Connect the 3-core cable (obtained locally) to the
ABC terminals.
Make a U-shaped cut-out in the center of the top
edge of the decorative cover and pass the 3-core
cable though the cut-out.
Remote Controller Cabling
Cabling diagram
For details of cabling/installation of the remote
controller, refer to the Installation Manual packaged
in the remote controller.
Terminal block
for remote controller
cabling of indoor unit
A
B
C
A
B
C
Remote controller cable
(Local procure)
Remote
controller unit
or sensor part
3-core cable,
obtained locally
Mounting screws (x 2)
obtained locally
3-core cable,
obtained locally
Mounting screws (x 2)
obtained locally
8