2 ACCESSORY PARTS
Part name Q’ty Shape Usage
Owner’s Manual 1 (Be sure to hand it to the customers.)
Installation Manual 2 (Be sure to hand it to the customers.)
CD-ROM
(Owner’s manual,
Installation manual)
1–
For other languages that do not appear in this Installation Manual,
Please refer to the enclosed CD-ROM.
Attached pipe
(for Ø22.2)
1
Connecting pipe for gas side piping
(MAP080, MAP100 type)
Attached pipe
(for Ø28.6)
1
Connecting pipe for gas side piping
(MAP120, MAP140, MAP160 type)
F-GAS label 1 Fill the items on the label after adding refrigerant.
3 INSTALLATION OF NEW REFRIGERANT
AIR CONDITIONER
This air conditioner adopts the new HFC refrigerant (R410A) which does not deplete the ozone layer.
R410A refrigerant is vulnerable to impurities such as water, oxidizing membranes, or oils because the pressure
of R410A refrigerant is higher than that of the former refrigerant by approximately 1.6 times.
As well as the adoption of the new refrigerant, the refrigerating oil has been also changed. Therefore, pay
attention so that water, dust, former refrigerant, or refrigerating oil does not enter the refrigerating cycle of the
new refrigerant air conditioner during installation.
To prevent mixing of refrigerant or refrigerating oil, the size of the charge port of the main unit or connecting
section of the installation tool differs to that of an air conditioner for the former refrigerant.
Accordingly, exclusive tools are required for the new refrigerant (R410A) as shown below.
For connecting pipes, use new and clean piping materials so that water or dust does not enter.
Required Tools and Cautions on handling
It is necessary to prepare the tools and parts for installation as described below. The tools and parts which will be
newly prepared in the following items should be restricted to exclusive use.
Explanation of symbols
: Newly prepared (It is necessary to use it exclusively with R410A, separately from those for R22 or R407C.)
: Former tool is available.
Used tools Usage Proper use of tools/parts
Gauge manifold
Vacuuming, charging refrigerant
and operation check
Exclusive to R410A
Charging hose Exclusive to R410A
Charging cylinder Charging refrigerant Unusable (Use the Refrigerant charging balance.)
Gas leak detector Checking gas leak Exclusive to R410A
Vacuum pump Vacuum drying
Usable if a counter-flow preventive adapter is
attached
Vacuum pump with counterflow Vacuum drying R22 (Existing article)
Flare tool Flare processing of pipes Usable by adjusting size
Bender Bending processing of pipes R22 (Existing article)
Refrigerant recovery device Recovering refrigerant Exclusive to R410A
Torque wrench Tightening flare nut Exclusive to Ø12.7mm and Ø15.9mm
Pipe cutter Cutting pipes R22 (Existing article)
Refrigerant canister Charging refrigerant
Exclusive to R410A
Enter the refrigerate name for identification
Welding machine/Nitrogen gas
cylinder
Welding of pipes R22 (Existing article)
Refrigerant charging balance Charging refrigerant R22 (Existing article)