Toshiba MMK-AP0092H Air Conditioner User Manual


 
9
6
INDOOR UNIT FIXING
7
DRAINAGE
1. Pass the pipe through the hole in the wall, and hook the
indoor unit on the installation plate at the upper hooks.
2. Swing the indoor unit to right and left to confirm that it is firmly
hooked up on the installation plate.
3. While pressing the indoor unit onto the wall, hook it at the
lower part on the installation plate. Pull the indoor unit toward
you to confirm that it is firmly hooked up on the installation
plate.
For detaching the indoor unit from the installation plate, pull the
indoor unit toward you while pushing its bottom up at the
specified parts.
CAUTION
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew- dropping.
This air conditioner has the structure designed to drain water collected
from dew, which forms on the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other parts at a height
above the drain guide.
1. Run the drain hose sloped downwards.
NOTE
Hole should be made at a slight downward
slant on the outdoor side.
2. Put water in the drain pan and make sure that
the water is drained out of doors.
3. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with shield pipe.
50 mm
or more
Do not put the
drain hose end
into water.
Do not put the
drain hose end in
the drainage ditch.
Do not form the drain hose
into a wavy shape.
Do not rise the drain hose.
Extension drain hose
Inside the
room
Drain hose
Shield pipe
Wall
Drain
guide
Space for pipes
Hook
1
Installation plate
Hook here
Press
(unhook)
1
2
PushPush