TIC-LF502A
4
Installation
■
Dimensions
Separate type LF502 (Meter size 6” and 8”)
Unit: inch (mm)
1.57 (40)
4.96 (126)
5.63 (143)
1.42 (36)
3.46 (88)
Figure 3. Detector Dimensions for Meter Sizes
6” (150 mm) and 8” (200 mm )
See the following tables for dimensions of L1, L2
and L3 in Figure 3 above, and the number of bolts
required for each flange.
ANSI 150 flange dimensions:
Meter
Size (inch)
L1
(inch)
L2
(inch)
L3
(inch)
No. of
bolts
Weight
(lb)
6 10.47 9.67 15.14 8 Approx.84
8 11.81 10.69 17.42 8 Approx. 194
JIS 10K flange dimensions:
Meter
Size (mm)
L1
(mm)
L2
(mm)
L3
(mm)
No. of
bolts
Weight
(kg)
150 266 246 386 8 Approx. 35
200 300 271 436 12 Approx. 80
■
Dimensions
Separate type LF502 (Meter size 10” to 24”)
Roll-prevention base
Unit: inch (mm)
3.46 (88)
1.57 (40)
1.42 (36)
5.63 (143)
4.96 (126)
11.81(300)
Figure 4. Detector Dimensions for Meter Sizes
10” (250 mm) to 24” (600 mm)
See the following tables for dimensions of L1, L2
and L3 in Figure 4 above, and the number of bolts
required for each flange.
ANSI 150 flange dimensions:
Meter
Size (inch)
L1
(inch)
L2
(inch)
L3
(inch)
No. of
bolts
Weight
(lb)
10 13.78 12.05 20.05 12 263
12 15.75 12.95 22.45 12 318
14 17.72 13.74 24.24 12 359
16 19.69 15.12 26.87 16 476
20 23.62 16.42 30.17 20 527
24 23.62 18.46 34.46 20 701
JIS 10K flange dimensions:
Meter
Size (mm)
L1
(mm)
L2
(mm)
L3
(mm)
No. of
Bolts
Weight
(kg)
250 350 306 506 12 Approx. 110
300 400 329 551 16 Approx. 120
350 450 351 596 16 Approx. 130
400 500 386 666 16 Approx. 180
500 600 403 740 20 Approx. 190
600 600 455 852 24 Approx. 250