Toshiba HWS-802XWHM3-E Heat Pump User Manual


 
142
Toshiba
6 Compressor
Compressor lead
10) Remove the discharge and suction pipes
connected to the compressor by using a burner.
WARNING
When removing the piping by burning the solder,
take enough care for a fire going off at the
moment the wax melts if oil remains inside the
piping.
Note)
Do not make fire flame contact with the 4-way
valve and pulse motor valve.
(This may cause an operation failure.)
11) Pull out the discharge and suction pipes of the
refrigerant cycle upward.
12) Remove the compressor bolts that fix the
compressor to the bottom board. (3 bolts)
13) Pull the compressor out toward you.
Note)
The compressor weighs 15 kg or more.
Two people should be required to handle it.
No.
Exchange parts
name
Work procedure Remarks
Remove
(Outlet pipe)
Compressor bolt
(3 bolts)
Remove
(Suction pipe)
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 142 Monday, October 5, 2009 2:09 PM